• English
    • العربية
  • English 
    • English
    • العربية
  • Login
View Item 
  •   DSpace Home
  • Faculty of Engineering & Technology
  • Articles
  • View Item
  •   DSpace Home
  • Faculty of Engineering & Technology
  • Articles
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Enhancement of Power Quality with Hybrid Distributed Generation and FACTS Device

View/Open
Enhancement of Power Quality with Hybrid Distributed.pdf (2.603Mb)
Date
2019-12-09
Author
Aljendy, Raseel
Nasyrov, Rinat R.
Abdelaziz, Almoataz Youssef
i Diab, Ahmed A. Zak
Metadata
Show full item record
Abstract
Renewable energy sources have been expected to be promising alternative energy sources in the future. Renewable energy sources can bring new challenges and problems when connected to the power grid. The basic elements of the PV– wind generating system are the DC–DC Boost Converter and the three-phase inverter whose role is to convert DC into AC having the same amplitude, fre- quency, and phase of the grid, to which it will be connected. Also, the injected power into an electric grid affects the power quality. Consequently, the impact of the integration of renewable power plants into the electric network corresponding to the level of harmonics and its propagation, besides the initial harmonics resulting from the nonlinear loads itself, has been presented in this paper. Firstly, the size of the distributed generators (DG) has been determined using the Salp Swarm algorithm (SSA) in order to improve the voltage profile and reduce the lack of generation. In addition, a techno- economic feasibility study of PV and wind power plant was evaluated using RETScreen program. Secondly, Active Power Filter (APF) has been used for power quality (PQ) improvement, where the controller for APF has been designed to improve the voltage profile and compensate reactive power and harmonics. Optimal parameters of APF (L-C) are determined using particle swarm optimization (PSO) to minimize the total harmonics distortion (THD) in the studied system. Furthermore, a com- prehensive comparison of the photovoltaic and wind generation with a nonlinear load in both cases with and without the APF is presented.
URI
http://repository.fue.edu.eg/xmlui/handle/123456789/5742
Collections
  • Articles [158]

DSpace software copyright © 2002-2016  DuraSpace
Contact Us | Send Feedback
All rights reserved to 
Atmire NV
 

 

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

LoginRegister

DSpace software copyright © 2002-2016  DuraSpace
Contact Us | Send Feedback
All rights reserved to 
Atmire NV